INTERGARD – GREY (GR3) – L (). Product Code:INTGRGL. Product Description: A two component, low VOC, high solids, fast curing epoxy. Intergard Epoxy Primer/Finish by International Paint – INTERGARD ULTRA DEEP BASE 1 GAL, VPN: AAA/1 for only $ Buy online or find out. Intergard _Datasheet – Download as PDF File .pdf), Text File .txt) or read online.

Author: Dugul Voodoogore
Country: Switzerland
Language: English (Spanish)
Genre: Art
Published (Last): 6 June 2017
Pages: 109
PDF File Size: 2.23 Mb
ePub File Size: 5.48 Mb
ISBN: 166-4-93833-812-2
Downloads: 76004
Price: Free* [*Free Regsitration Required]
Uploader: Daihn

Surface defects revealed by the blast cleaning process should be ground, filled, or treated in the appropriate manner. They have a team of dexterous professionals who has vast experience in this industry and hold expertise in their integard domain.

These products are used in various industrial applications and available in different colors.

Intergard provides a combination ofanti-corrosive barrier protection, chemical fume and spillage resistance, along interrgard good abrasion resistance. In common with all epoxies, Intergard will chalk and discolor on exterior exposure.

Akzonobel Intergard 345, Packaging Size: 20 L

In moderately corrosive environments, it is recommended that a minimum of 4 mils microns dry film thickness should be specified to ensure adequate anti-corrosive performance. Consult International Protective Coatings for further details. Number of Employees Upto 10 People.

These may be subject to variation depending on factors such as differences in color and normal manufacturing tolerances. Systems recommendation Intergard is normally applied directly to blast cleaned steel, however, it can also be applied directly over the following primers: Epoxy Zinc Chromate Primer.

  AVURUDU LITHA 2015 PDF

We as Exclusive Intergadd obtain these products from the Worlds No 1 Paint Company Akzonobel, who ensure all the products are manufactured using high-grade ingredients with minimum human errors.

However, in non-aggressive, low corrosive environments such as those equating to C2 as per ISO part 2, it is acceptable to specify Intergard as a single coat at 3. Intergard is suitable for application to blast cleaned surfaces which were initially to the above standard but have been allowed to deteriorate under good shop conditions for up to days.

Call Send a quick message. All poured and precast concrete must also be sweep blasted preferred or acid etched to remove laitence. Varnish Hybrid Water base. This phenomena is particularly prominent in darker shades. View Contact Call Seller Now. Concrete should be cured for a minimum of 28 days prior to coating. Do not thin more than allowed by local environmental legislation Mix ratio 4 part s: Film thickness requirement wet: The surface may deteriorate to Sa2 standard but must be free from loose powdery deposits.

Epoxy Zinc Rich Primer. I agree to the terms and privacy policy.

Intergard provides a combination of anti-corrosive barrier protection, chemical fume and spillage resistance, along with good abrasion resistance. Press and move to zoom. Condensation occurring during or immediately after application may result in a matte finish and an inferior film.

Akzonobel Intergard , Packaging Size: 20 L, Rs /litre | ID:

Be the first to write a review for this product! Driying time full curing: When utilizing certain colors, particularly the darker shades via the Chromascan system where maximum addition of colorants is required, it is necessary to allow an increase in the quoted drying and overcoating times.

  KALINA BARTNICKA ZARYS HISTORII WYCHOWANIA PDF

If oxidation has occurred between blasting and application of Intergard the surface should be reblasted to the specified visual standard. Film thickness requirement dry: Get in Touch with us Namit Enterprises. Epoxy Zinc Rich Primer in Faridabad. Our array is well known all across the market for their splendid features such as quality and efficiency.

International Intergard 345 Epoxy Primer / Finish Coating

Concrete, Pre-cast Blockwork, etc Intergard is suitable for application to concrete. How to use Mixing Material is intwrgard in two containers as a unit. All surfaces should be clean, dry and free from curing compounds, release agents, trowelling compounds, surface hardeners, efflorescence, grease, oil, dirt, old coatings and loose or disintegrating concrete. When applying by methods other than airless spray, the required film build is unlikely to be achieved.

Prior to paint application, all surfaces should be assessed and treated in accordance with ISO Drying time dust free: Get Best Price Request a quote. Once the unit has been mixed, it must be used within the working pot life specified.

VOC values are typical and are provided for guidance purpose only.

Year of Establishment Drying time touch dry: However, these phenomena are not detrimental to anti-corrosive performance. Epoxy Zinc Phosphate Primer.